ABSTRACT

ABSTRACT: The apical limit of tooth roots for instrumentation and obturation is a controversial subject due to the high morphological complexity presented by the apical zone of the root. The development of electronic apex locators (EALs) has made working length (WL) determination more predictable, producing more accurate results; however, the interpretation mechanisms of different devices may affect measurements taken under different clinical conditions. One hundred premolars were used to compare the effectiveness of Propex II, Raypex 6, Propex Pixi and Root ZX II in locating the apical foramen (AF). No statistically significant differences were observed when the accuracy of measurement was compared between the different groups of EALs, however Root ZX II and Raypex 6 presented the best overall performance.


RESUMEN: El límite apical radicular para la instrumentación y obturación es un tema controversial, debido a la alta complejidad morfológica que presenta la zona apical de la raíz. El desarrollo de localizadores de ápice electrónicos (EALs) ha hecho la determinación de la longitud de trabajo (WL) más predecible y con resultados más precisos. Sin embargo, el mecanismo de interpretación de cada dispositivo puede afectar la determinación de las mediciones en diferentes condiciones clínicas. Cien premolares fueron utilizados para comparar la efectividad de Propex II, Raypex 6, Propex Pixi y Root ZX II en localizar el foramen apical (AF). No se observaron diferencias estadísticamente significativas cuando se comparó la precisión de medición entre los diferentes grupos de EALs, sin embargo, Root ZX II y Raypex 6 mostraron un mejor desempeño global.


Subject(s)
Humans , Root Canal Preparation/instrumentation , Tooth Apex/anatomy & histology , Dental Pulp Cavity/anatomy & histology , Electrical Equipment and Supplies/standards , Odontometry/instrumentation , Chile , Tooth Apex/diagnostic imaging , Dental Pulp Cavity/diagnostic imaging
2.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 29(2): 78-81, mai.-jun.2016. ilus
Article in Portuguese | LILACS | ID: lil-794474

ABSTRACT

Durante anos, o tratamento com radioterapia de portadores de dispositivos eletrônicos implantáveisfoi considerado perigoso. Se a zona a ser irradiada envolvesse o lado em que o dispositivo estivesse localizado, aestratégia envolvia inclusive mudanças no local do implante. Passaram-se os anos e tanto os dispositivos como aradioterapia evoluíram, e o que antes era regra para a segurança do binômio marcapasso-radioterapia hoje pode serexceção. Relatamos o caso de um paciente portador de neoplasia maligna de lobo superior de pulmão direito, emposição ipsilateral ao marcapasso implantado previamente...


For years treatment with radiotherapy in patients with implantable electronic devices was considered dangerous. If the area to be irradiated involved the side where the device was located, the strategy involved including changes at the implant site. The years have gone by, the devices have evolved, radiotherapy has evolved,and what used to be the safety rule for the pacemaker-radiotherapy binomial may be the exception today. We report the case of a patient with malignant neoplasia of the upper lobe of the right lung, ipsilateral to a previously implanted pacemaker...


Subject(s)
Humans , Male , Aged , Lung Neoplasms/diagnosis , Lung Neoplasms/therapy , Pacemaker, Artificial , Patients , Radiotherapy/methods , Electrical Equipment and Supplies/standards
3.
Rev. salud pública ; 12(1): 126-134, feb. 2010. ilus
Article in Spanish | LILACS | ID: lil-552325

ABSTRACT

Objetivo Analizar los aspectos metrológicos fundamentales que se deben tener en cuenta en la elaboración de los procedimientos de calibración de equipo electromédico, que permitan acreditar en Colombia, laboratorios de metrología electromédica con base en la normatividad internacional. Métodos Con base en las normas NTC-ISO-IEC 17025:2005 y GTC-51, se diseñaron e implementaron procedimientos para la calibración de equipo electromédico, contando para ello con un conjunto completo de analizadores de equipos electromédicos que fueron utilizados como patrones. Resultados El modelo matemático para determinar el valor estimado de incertidumbre en la calibración de equipos electromédicos, para la acreditación del área de Calibración de Equipos Electromédicos del Laboratorio de Metrología de Variables Eléctricas, acreditado según Resolución 25771 del 26 mayo de 2009 de la Superintendencia de Industria y Comercio, consta de dos ecuaciones según sea el caso; ellas son: y Conclusión El modelamiento matemático implementado para el cálculo de incertidumbre de medición en el proceso de acreditación del área de calibración de equipos electromédicos del Laboratorio de Metrología de Variables Eléctricas, de la Universidad Tecnológica de Pereira, constituye una buena guía para futuros procesos de calibración que emprendan otros laboratorios de Colombia y Latinoamérica.


Objective Analysing the fundamental methodological aspects which should be considered when drawing up calibration procedure for electro-medical equipment, thereby permitting international standard-based accreditation of electro-medical metrology laboratories in Colombia. Methods NTC-ISO-IEC 17025:2005 and GTC-51-based procedures for calibrating electro-medical equipment were implemented and then used as patterns. Results The mathematical model for determining the estimated uncertainty value when calibrating electro-medical equipment for accreditation by the Electrical Variable Metrology Laboratory's Electro-medical Equipment Calibration Area accredited in compliance with Superintendence of Industry and Commerce Resolution 25771 May 26th 2009 consists of two equations depending on the case; they are: and Conclusion The mathematical modelling implemented for measuring uncertainty in the Universidad Tecnológica de Pereira's Electrical Variable Metrology Laboratory (Electro-medical Equipment Calibration Area) will become a good guide for calibration initiated in other laboratories in Colombia and Latin-America.


Subject(s)
Accreditation , Calibration/standards , Electrical Equipment and Supplies/standards , Laboratories/standards , Colombia , Mathematics , Reproducibility of Results